b = 20in
h = 20in
Properties of the selected FRP reinforcement
Type_of_Fiber :=
Bar_Size :=
#2
#3
#4
#5
#6
#7
#8
#9
#10
Glass
Carbon
The manufacturer's guaranteed mechanical properties are the following:
f fuu = 80·ksi
Ultimate guaranteed tensile strength of the FRP
ε fuu = 0.01404
Ultimate guaranteed rupture strain of the FRP
E f = 5700·ksi
Guaranteed tensile modulus of elasticity of the FRP
The geometrical properties of the selected bar are
ϕ f _ bar = 1·in.
Bar diameter
A f _ bar = 0.785·in. 2
Bar area
FRP reduction factors: Table 7-1 of ACI 440.1R-06 is used to define the
environmental reduction factor, C E . The type of exposure has to be selected:
Type_of_Exposure :=
Interior
Exterior
Search WWH ::