Civil Engineering Reference
In-Depth Information
The minimum development length is computed according to ACI 440.1R-
06 Equation (11-6):
f
f'
fu
α⋅
−
340
Pos
⋅
psi
c
.
1:
=
φ=
25.364 in
⋅
d_min
C
f_bar
b2
13.6
+
φ
f_bar
The following development length is considered and is available to pro-
vide the required moment capacity:
l
d
:= 26 in.
6.6.3 Case 3—Interior support
Reinforcement required to resist bending moments:
The same procedure
discussed for case 1 is followed.
The effective reinforcement depth is
=−−
φ
f_bar
d:t
c
=⋅
7 n
.
f3
slab
c
2
ϕ-factor
ϕ
b
_
trial
= 0.65
The longitudinal reinforcement ratio required for bending is
M
1
bd
(
)
u3
ρ
:
=
⋅
0.00292
M7kipft
=⋅
⋅
f_req_bend3
u3
β
⋅
1
φ⋅
f
⋅
d
2
⋅
0.15d
f3
b_trial
fu
f3
f3
The minimum reinforcement requirement has to be verified. Equation
(8-8) of ACI 440.1R-06 is used. If the failure is not governed by FRP rup-
ture, this requirement is automatically achieved:
4.9fpsi
f
⋅
′ ⋅
bd ,
300psi
f
c
(
)
2
A:
=
ρf_min3)
⋅
bd
⋅
=
0.315 in
⋅
f_min3
f3
f3
fu
fu
A
bd
f_min3
ρ
:
=
=
0.00375
f_min3
⋅
f1
The design reinforcement ratio required for bending is taken as
ρ
f_bend3
:= max (ρ
f_red_bend3
,
ρ
f_min3
) = 0.00375
Reinforcement required for concrete shear strength:
The same procedure
discussed for Case 1 is followed.
Search WWH ::