Civil Engineering Reference
In-Depth Information
The minimum development length is computed according to ACI 440.1R-
06 Equation (11-6):
f
f'
fu
α⋅
340
Pos
psi
c
.
1:
=
φ=
25.364 in
d_min
C
f_bar
b2
13.6
+ φ
f_bar
The following development length is considered and is available to pro-
vide the required moment capacity:
l d := 26 in.
6.6.3 Case 3—Interior support
Reinforcement required to resist bending moments: The same procedure
discussed for case 1 is followed.
The effective reinforcement depth is
=−− φ
f_bar
d:t
c
=⋅
7 n
.
f3
slab
c
2
ϕ-factor
ϕ b _ trial = 0.65
The longitudinal reinforcement ratio required for bending is
M
1
bd
(
)
u3
ρ
:
=
0.00292
M7kipft
=⋅
f_req_bend3
u3
β
1
φ⋅
f
d 2
0.15d
f3
b_trial
fu
f3
f3
The minimum reinforcement requirement has to be verified. Equation
(8-8) of ACI 440.1R-06 is used. If the failure is not governed by FRP rup-
ture, this requirement is automatically achieved:
4.9fpsi
f
′ ⋅
bd , 300psi
f
c
(
)
2
A:
=
ρf_min3)
bd
=
0.315 in
f_min3
f3
f3
fu
fu
A
bd
f_min3
ρ
:
=
=
0.00375
f_min3
f1
The design reinforcement ratio required for bending is taken as
ρ f_bend3 := max (ρ f_red_bend3 , ρ f_min3 ) = 0.00375
Reinforcement required for concrete shear strength: The same procedure
discussed for Case 1 is followed.
Search WWH ::