ACI 318-11). For fiber-reinforced concrete (FRC) RC flexural members, the
relationship between reinforcing ratio and its tensile strain is
f
f
ε
ε+ε
c
f
cu
ρ=
0.85 1
β
(4.49)
f
cu
f
Therefore,
ρ
ρ
f
f
ε+ε
ε+ε
ε
ε
ε+ε
ε+ε
f
fu
cu
fu
fu
cu
fu
=
=
(4.50)
fb
f
cu
f
f
cu
f
And the strength-reduction factor can be reformulated as
ε
ε
ε+ε
ε+ε
fu
cu
fu
0.55
≤φ=
0.30
+
0.25
0.65
(4.51)
f
cu
f
The strength-reduction factor expressed by Equation (4.51) is calibrated
by targeting a level of reliability of at least 3.5. This target reliability,
however, is not always obtainable even by ordinary steel RC flexural
members [13].
4.6.2 New approach
An attempt by Jawaheri Zadeh and Nanni [14] to equalize the reliability
indices of the two member types (steel RC vs. FRP RC) leads to ϕ with a
lower limit of 0.70 (instead of 0.55) and an upper limit of 0.75 (instead of
0.65). Based on a conservative interpretation of these values, a new ϕ may
be formulated as
ε
ε
f
(4.52)
0.65
≤φ=
1.15
0.75
2
fu
It should be noted that ACI 318-11 also imposes a strength-reduction fac-
tor of ϕ = 0.65 on compression-controlled sections, which is lower than the
value (0.75) proposed by Equation (4.52). Nevertheless, a reliability-based
calibration of the strength-reduction factors of steel RC members [13] con-
firms the adequacy of ϕ = 0.75. Figure  4.10 compares the two ϕ-factors
(Equation 4.51 vs. Equation 4.52) for different levels of maximum tensile
strain if ε fu = 0.01.
In the design examples presented in Chapters 6-8 and 10, the values
of ϕ M n computed according to both methods (i.e., ACI 440.1R-06 and
Jawaheri Zadeh and Nanni [14]) are shown.