Information Technology Reference
In-Depth Information
To record a web application session and then create a synthetic monitor based on that
information, perform the following steps:
1.
In the Authoring workspace of the Operations Manager console, select Web Applica-
tion Transaction Monitoring under Management Pack Templates.
In the Tasks menu, click Custom Actions, and then click Record A Browser Session.
2.
On the Web Application Editor, shown in Figure 2-52, provide a name and select an
unsealed management pack in which to store the session information.
3.
FIGURE 2-52 Web application editor
On the Web Application Editor - Browsing Session dialog box, click Start Capture. In-
ternet Explorer will launch. Browse to the web application and perform the interaction
that you want to test.
4.
When you complete the browsing session, close the browser, click Stop Capture, click
Apply on the Web Application Editor, then select a watcher node, and click Apply
again. Verify that the Web Application Data Imported Successfully message is dis-
played, as shown in Figure 2-53, and then close the Web Application Editor dialog box.