Table SH2.1 Building Wrap Selection Criteria for the Home Depot Smart Home at Duke
University, Including Test Method
Air
Penetration Water
Water-
(cfm/ft 2 at Resistance
Vapor
UV
Resistive
Building
75 Pa) by
(cm) by Transmission
Exposure
Barrier by
Wrap
ASTM AATCC-
(perms) by
Tolerance
ICC/ASTM
Product
E2178
127
ASTM E96
(days)
d226
Vaproshield
0.002
68
212
UV stable
ICC ES
Certified
Tyvek Homewrap
0.007
210
58
120
ICC ES
Certified
Ty v e k
Commercialwrap
0.001
280
28
270
ICC ES
Certified
n/a a
Grace Ice and Water
Shield
n/a
0.05
30
n/a
No. 15 asphalt felt
n/a
52
8
n/a
yes
Recommended for
rain screen
< 0.004
> 55
> 20
Low or no
degradation
Required
a n/a, not available.
Questions
1. How does this material selection process differ under the traditional stepwise
design process and the integrated green design process? How may the
criteria be applied using computer models (e.g. BIM)?
2. What other types of passive and active systems can be used to design building
wraps?
3. How might sensors be used to enhance these processes?
Resources
ASTM E2178: http://www.astm.org/cgi-bin/SoftCart.exe/DATABASE.CART/
REDLINE PAGES/E2178.htm?L
pyfx6202
Rain Screen prose: http://irc.nrc-cnrc.gc.ca/pubs/ctus/34 e.html
AATC test method 127-2003: http://www.aatcc.org/Technical/Test Methods/scopes/
tm127.cfm
AATC E96M-05: http://www.astm.org/cgi-bin/SoftCart.exe/DATABASE.CART/
REDLINE PAGES/E96E96M.htm?L
+
mystore
+
+
mystore
+
bfks2207
ICC-ES reports: http://www.icc-es.org/
Source: This example was provided by Tom Rose, Director of the Duke Smart Home Program.
 