Biomedical Engineering Reference
In-Depth Information
Udel
®
:
Polysulfone made by General Electric.
Valence electrons:
The outermost (shell) electrons of an atom.
van der Waals bonding:
A secondary bonding arising through the fluctuating dipole-dipole interactions.
Vinyl polymers:
Thermoplastic linear polymers synthesized by free radical polymerization of vinyl
monomers having a common structure of CH
2
∙
CHR.
Vulcanization:
Cross-linking of a (natural) rubber by adding sulfur.
Ziegler-Natta catalyst:
Organometallic compounds which have the remarkable capacity of polymer-
izing a wide variety of monomers to linear and stereoregular polymers.
Acknowledgments
This work was supported by grants from the Korean Ministry of Health and Welfare (grant Nos.
HMP-95-G-2-33 and HMP-97-E-0016) and the Korean Ministry of Science and Technology (grant No.
97-N1-02-05-A-02).
References
Baier, R.E., Meyer, A.E., Natiella, J.R., Natiella, R.R., and Carter, J.M. 1984. Surface properties determine
bioadhesive outcomes: methods and results,
J. Biomed. Mater. Res.
, 18: 337-355.
Billmeyer, F.W. Jr. 1984.
Textbook of Polymer Science
, 3rd ed. Wiley, New York.
Block, S.S. (Ed.) 1977.
Disinfection, Sterilization, and Preservation
, 2nd ed. Rea and Febiger, Philadelphia, PA.
Brandrup, J. and Immergut, E.H. (Eds.) 1989.
Polymer Handbook
, 3rd ed. Wiley-Interscience, New York.
Branger, B., Garreau, M., Baudin, G., and Gris, J.C. 1990. Biocompatibility of blood tubings,
Int. J. Artif.
Organs
, 13: 697-703.
Dumitriu, S. (Ed.) 1993.
Polymeric Biomaterials
, Marcel Dekker, New York.
Elwing, E., Askendal, A., and Lundstorm, I. 1989. Desorption of fibrinogen and γ-globulin from solid sur-
faces induced by a nonionic detergent,
J. Colloid Interface Sci.
, 128: 296-300.
Glaser, Z.R. 1979. Ethylene oxide: Toxicology review and field study results of hospital use,
J. Environ.
Pathol. Toxicol.
, 2: 173-208.
Hoffman, A.S. 1981. Radiation processing in biomaterials: A review,
Radiat. Phys. Chem.
, 18: 323-340.
Iwasaki, Y., Ishihara, K., Nakabayashi, N., Khang, G., Jeon, J.H., Lee, J.W., and Lee, H.B. 1997. Preparation
of gradient surfaces grafted with phospholipid polymers and evaluation of their blood compatibility.
In:
Advances in Biomaterials Science
, Vol. 1, T. Akaike, T. Okano, M. Akashi, M. Terano, and N. Yui,
Eds. pp. 91-100, CMC Co., Ltd., Tokyo.
Jeong, B.J., Lee, J.H., and Lee, H.B. 1996. Preparation and characterization of comb-like PEO gradient sur-
faces.
J. Colloid Interface Sci.
, 178: 757-763.
Jozefowicz, M. and Jozefowicz, J. 1985. New approaches to anticoagulation: Heparin-like biomaterials.
J. Am. Soc. Art. Intern. Org.
8: 218-222.
Keogh, J.R., Valender, F.F., and Eaton, J.W. 1992. Albumin-binding surfaces for implantable devices,
J. Biomed. Mater. Res.
, 26: 357-372.
Khang, G., Park J.B., and Lee, H.B. 1996a. Prevention of platelet adhesion on the polysulfone porous cath-
eter by saline perfusion, I.
In vitro
investigation,
Bio-Med. Mater. Eng.
, 6: 47-66.
Khang, G., Park, J.B., and Lee, H.B. 1996b. Prevention of platelet adhesion on the polysulfone porous
catheter by saline perfusion, II.
Ex vivo
and
in vivo
investigation,
Bio-Med. Mater. Eng.
, 6: 123-134.
Khang, G., Lee, H.B., and Park, J.B. 1996c. Radiation effects on polypropylene for sterilization,
Bio-Med.
Mater. Eng.
, 6: 323-334.
Khang, G., Kang, Y.H., Park, J.B., and Lee, H.B. 1996d. Improved bonding strength of polyethylene/poly-
methylmethacrylate bone cement—A preliminary study,
Bio-Med. Mater. Eng.
, 6: 335-344.
Khang, G., Jeon, J.H., Lee, J.W., Cho, S.C., and Lee, H.B. 1997a. Cell and platelet adhesion on plasma glow
discharge-treated poly(lactide-
co
-glycolide),
Bio-Med. Mater. Eng.
, 7: 357-368.