Biomedical Engineering Reference
In-Depth Information
16
riley M a, Walmsley a D, speight J D and Harris I r, 'Magnets in medicine',
Mater Sci Technol
, 2002,
18
, 1-12.
17
Watanabe I, Hai K, Tanaba Y, Hisatsune K and atsuta M, '
In vitro
corrosion behaviour
of cast iron-platinum magnetic alloys',
Dent Mater
, 2001,
17
, 217-20.
18
riley M a, Walmsley a D and Harris I r, 'Magnets in prosthetic dentistry',
J
prosthet Dent
, 2001,
86
, 137-42.
19
Gillings B r D, 'Magnetic retention for complete and partial over-dentures: Part
2',
J prosthet Dent
, 1983,
49
, 607-18.
20
Takada Y and okuno o, 'Corrosion behavior of stainless steels and dental precious
alloys used for dental magnetic attachments',
J Mag Dent
, 1994,
3
(1), 14-22.
21
Flores M s, Ciapetti G, González-Carrasco J L, Montealegre M a, Multigner M,
Pagani s and rivero G, 'evaluation of magnetic behavior and
in vitro
biocompatibility
of ferritic PM 2000 alloy',
J Mater Sci: Mater Med
, 2004,
15
, 1-7.
22
González-Carrasco J L, García-alonso M C, Montealegre M a, escudero M L
and Chao J, 'Comparative study of the alumina scale integrity on Ma 956 and
PM 2000, alloys',
Oxid Met
, 2001,
55
(3/4), 209-21.
23
Laakman r W, Kaufman B, Han J s, nelson a D, Clampitt M, o'Block a M, Haaga
J R and Alfidi R J, 'MR imaging in patients with metallic implants',
Radiology
,
1985,
157
(3), 711-4.
24
Da rocha s s, adabo G L, Vaz L G and Henriques G e, 'effect of thermal
treatments on tensile strength of commercially cast pure titanium and Ti-6al-4V
alloys',
J Mater Sci: Mater Med
, 2005,
16
, 759-66.
25
Hall e o, 'The deformation and ageing of mild steel: III Discussion of results',
proc. phys. Soc.
(London), 1951,
64B
, 747-53.
26
Petch n J, 'The cleavage strength of polycristals',
J Iron Steel Inst (London)
, 1953,
3
, 25-8.
27
Fleming D G and Feinberg B n (eds),
Handbook of Engineering in Medicine and
biology
, CrC Press, Boca raton, FL, 1976.
28
Callister W D (ed.),
Materials Science and Engineering. An Introduction
, John
Wiley & sons, new York, 2003.
29
ASM Metals Handbook
,
Vol 3: properties and Selection: Stainless Steels, Tool
Materials and Special-purpose Materials
, asM International, Metals Park, Usa,
1985.
30
Turner n G and roberts W T, 'Fatigue behavior of titanium',
Trans. TMS-AIME
,
1968,
242
, 1223- 30.
31
Kuhlman G W, in:
Microstructure/property Relationships in Titanium Aluminides
and Alloys
, Kim Y-W and Boyer rr (eds), TMs, Warrendale, Pa, 1991,
p 465.
32
Jaffe r I and Lutjering G, in
Microstructure, fracture Toughness and fatigue
Crack Growth Rate in Titanium Alloys
, Chakrabarti aK, Chestnut JC (eds), TMs,
Warrendale, Pa, 1987, p 193.
33
sivakumar M, suresh Kumar Dhanadurai K, rajeswari s and Thulasiraman V,
'Failures in stainless steel orthopaedic implant devices: a survey',
J Mater Sci
Lett
, 1995,
14
, 351-4.
34
Chao J and López V, 'Failure analysis of a Ti-6al-4V cementless HIP prosthesis',
Engineering failure Analysis
, 2007,
14
(5), 822-30.
35
Viceconti M, Toni a and Giunti a, 'effects of some technological aspects on
the fatigue strength of a cementless hip stem',
J biomed Mater Res
, 1995,
29
,
875-81.