Environmental Engineering Reference
In-Depth Information
Answers to Text Questions
Question #2.1
Cable area =
/4 × (7/32) 2 = 0.03758 sq in.
Differential pressure = 4,986 psi.
π
(a) Upward force = 4,986 × 0.03758 = 187.4 lb.
(b) Weights required = (187.4 − 20)/26 = 6.44.
(c) So use seven weights.
(d) Riser requirements = 16-ft tool + (7 × 4 ft) = 44 ft.
(e) Rig height = 10 + 44 + 10 + 6 = 70 ft.
Question #2.2
(a) The well must be shut in before tools can be run in or out of the well.
(b) No effect on ability to log well.
(c) To bleed off pressure in the riser before undoing the quick-connect riser
connection.
Question #2.3
500 B/D
Search WWH ::