Fig. 12.19
Casing OD weight and thickness
Partial Cementation
The case where a section of pipe shows an amplitude higher than the minimum
amplitude read in well-cemented pipe raises the possibility that a hydraulic seal
does not exist. To quantify the analysis, a bond index is used:
(
)
Attenuation in suspectzone
dB
/
ft
Bond index
=
(
)
Attenuation in well
cemented zone
dB
/
ft
Experience shows that if the bond index is at least 0.8 a seal can be expected, pro-
vided the poorly bonded section is suffi ciently long. Figure 12.20 shows that the
larger the casing size, the longer the interval needed at or above the bond index = 0.8
condition for a seal to be assured. A rough rule of thumb is to double the casing size
in inches and subtract 5 to give the number of feet of section required.
 