Metric
Devices
Notes
Number
Condensation
Particle Counter
(CPC)
Real-time particle number concentration measurements
between
10 nm and 1
m.
>
µ
Scanning Mobility
Particle Sizer
(SMPS)
Real-time (mobility diameter) measurement of aerosol
size distribution - interpreted as number
concentration.
Electrical Low
Pressure
Impactor (ELPI)
Real-time size selective (aerodynamic diameter) measure-
ment of size distribution. Size selected samples may be
further analysed off-line.
Optical Particle
Counter (OPC)
Real-time number concentration measurement of
particles larger than
300 nm in diameter. When used
with a CPC, OPCs may offer insight into the number
concentration of particles smaller than
300 nm.
Electron
Microscopy
Off-line analysis of aerosol number concentration (and
other parameters).
Mass
Size selective
personal sampler
Off-line gravimetric or chemical analysis of fi lter or
impactor samples. Some cascade impactors have lower
stages which sample particles
<
100 nm.
Size selective static
sampler
Off-line gravimetric or chemical analysis of fi lter or
impactor samples. Some cascade impactors have lower
stages which sample particles
<
100 nm aerodynamic
diameter.
Tapered Element
Oscillating
Microbalance
(TEOM)
Sensitive real-time monitors such as the TEOM may be
useable to measure nanoaerosol mass concentration
on-line, with a suitable size selector inlet.
Scanning Mobility
Particle Sizer
(SMPS)
Real-time (mobility diameter) measurement of aerosol
size distribution. Data may be interpreted in terms of
aerosol mass concentration, only if particle shape and
density are known.
Electrical Low
Pressure
Impactor (ELPI)
Real-time size selective (aerodynamic diameter) measure-
ment of size distribution. Data may be interpreted in
terms of mass concentration if particle charge and
density are known. Size selected samples may be
further analysed off-line.
Specifi c
surface
area
Scanning Mobility
Particle Sizer
(SMPS)
Real-time (mobility diameter) measurement of size
distribution - interpreted as specifi c specifi c surface
area concentration (Rogak et al. , 1993).
Electrical Low
Pressure
Impactor (ELPI)
Real-time size selective (aerodynamic diameter) measure-
ment of active specifi c specifi c surface area. Size
selected samples may be further analysed off-line.
SMPS and ELPI
used in parallel
Differences in measured aerodynamic and mobility
diameter can be further used to estimate surface area.
Diffusion Charger
Real-time measurement of aerosol active surface area.
Active specifi c surface area scales as particle diameter
squared below
100 nm, and particle diameter to the
power 1 above
m. Some commercial devices tailor
the response to particle specifi c surface area depositing
in selected regions of the lungs.
1
µ
Electron
Microscopy
Off-line analysis of aerosol specifi c surface area concen-
tration (and other parameters). Specifi c surface area is
derived form a two-dimensional projection when using
transmission electron microscopy.
 