Environmental Engineering Reference
In-Depth Information
Maximum defect size, %
9.25 Probabilities of large-scale failure of heat exchanger tubes
in relation to the maximum defect size for steam generator No. 4:
1) realistic appoach; 2) conservative estimate; 3) permissible level.
￿ ￿ ￿ ￿ ￿
Table 9.10 Justification of serviceability of steam generator heat exchanger
tubes of VVER-440 reactors
Minimum permissible defect depth, %
Novovoronezh NPP
Steam generator
No.
Kola NPP
Unit No. 3
Unit No. 4
Unit No. 1
Unit No. 2
1
60
79
67
67
2
58
71
68
67
3
61
67
69
66
4
55
70
65
68
5
60
74
76
65
6
63
58
75
65
 
Search WWH ::