Environmental Engineering Reference
In-Depth Information
Table 9.2 Number of plugged HET on the existing HSG in the USA 
Num-
ber of
HET in
SGs
Num-
ber of
plugged
HET
Num-
ber of
SGs
Start
year
Output,
MW
Company, type
of SG
Year re-
placed
Nuclear power plant
1974
Arkansas One-1
836
B&W, FA177
2
15531
2005
1704
1976
Beaver Valley-1
810
WEST, M51M
3
3388
2006
1952
1987
Beaver Valley-2
820
WEST, M51M
3
3388
440
1990
Comanche Peak-1
1150
WEST, D4
4
4578
2007
776
1977
Crystal River-3
818
B&W, FA177
2
15531
2009
1213
1978
Davis Besse-1
873
B&W, FA177
2
15531
823
1985
Diablo Canyon-1
1073
WEST, M51
4
3388
2009
825
1986
Diablo Canyon-2
1087
WEST, M51
4
3388
2008
890
1974
Fort Calhoun
476
CE, S67
2
| 5005
| 2006
| 753
1990
Palisades
762
CE, M2350
2
8219
823
1980
Palo Verde-1
1270
CE, S80
2
11012
2005
2076
1988
Palo Verde-3
1270
CE, S80
2
11012
2007
1500
1974
Prainie Island-2
512
WEST, M51
2
3388
500
1981
Salem-2
1106
WEST, M51
4
3388
2006
1100
1983
San Onofre-2
1070
CE-3410
2
9350
2009
2383
1984
San Onofre-3
1080
CE-3410
2
9350
2010
1355
1982
Sequoyah-2
1106
WEST, M51
4
3388
507
￿ ￿ ￿ ￿ ￿
1983
St. Lucie-2
839
CE, S3410
2
8519
2007
4268
1973
Three Mile Island-1
786
B&W, FA177
3
15531
2009
2532
1985
Waterford-3
1075
CE, CE70
2
9350
2005
1524
1996
Watts Bar-1
1170
WEST, D3
4
4674
2006
1158
of the 70s holds a special place in their analysis of US speciliasts. It is
this type of corrosion that besides SG HET (from inside) affects primary
circuit equipment. This type of corrosion taking place in the US SGs was
first recorded in the early 70's. Its contribution to the number of defects,
which required repair, has changed over time, reaching 40%. This type
of corrosion has led to the rupture of HET in 1976 at Surry-2 NPP in
the USA, in 2000 at Indian Point-2 NPP (and also in 1979, at Doel-2
NPP in Belgium). In VSG HETs in the United States this mechanism is
 
Search WWH ::