Environmental Engineering Reference
In-Depth Information
Table 7.3 Requirements on in-service inspection of the pressuriser
Strength
criterion
Inspection parameter
Permissible value of parameter
Inspection frequency
Nominal
-
According to
actual state
142 mm
Nominal
-
According to
actual state
160 mm
1. Pressure
2. Temperature
3. Tensile strength
4. Wall thickness
Continuous
-
> 30 years
> 30 years
Ductile
fracture
resistance
Nominal >100 o
in HT
According to
actual state
142 mm
8 mm
160
Nominal >170 o
in HT
According to
actual state
160 mm
14 mm
160
in HT conditions
In HT conditions
> 30 years
in HT conditions
In HT conditions
> 30 years
1. Pressure
2. Temperature
3. Tensile strength
4. Wall thickness
5. Crack length L
6. Number of cycles N
Quasi-
brittle
fracture
resistance
> 30 years
1 in 4 years
Continuous
> 30 years
1 in 4 years
Continuous
Brittle
fracture
resistance
1. Pressure
2. Temperature
Nominal
Nominal
During heating
During heating
726
726
726
726
1. Number of start-shutdown cycles
2. Number of hydraulic pressing cycles
3. Number of hydraulic tests
Fatigue
strength
Continuous
Continuous
88
88
 