Environmental Engineering Reference
In-Depth Information
a)
2
c
, mm
b)
2
c
, mm
c)
2
c
, mm
d)
5.39
Experimental histogram and calculated curves of the detection
of defects: a) 1
st
inspection, 2) 2
nd
inspection, 3) 3
rd
inspection, 4)
4
th
inspection.
the results of the forecasts is shown in Fig. 5.39. Figure 5.39a shows the
function
N
det
for the cladding of one of the casings of the VVER-1000
reactor constructed on the basis of the inspection results. The following
values of the parameters are determined from the condition of maximal
proximity of the function [5.21] to the experimental data
A
= 1.482 mm
1;17
;
n
= 2; 17,
a
= 0.034 mm
-1
.
Figure 5.39b shows the curve calculated from equation [5.22] for