a)
2 c , mm
b)
2 c , mm
c)
￿ ￿ ￿ ￿ ￿
2 c , mm
d)
5.39 Experimental histogram and calculated curves of the detection
of defects: a) 1 st inspection, 2) 2 nd inspection, 3) 3 rd inspection, 4)
4 th inspection. 
the results of the forecasts is shown in Fig. 5.39. Figure 5.39a shows the
function N det for the cladding of one of the casings of the VVER-1000
reactor constructed on the basis of the inspection results. The following
values of the parameters are determined from the condition of maximal
proximity of the function [5.21] to the experimental data
A = 1.482 mm 1;17 ; n = 2; 17, a = 0.034 mm -1 .
Figure 5.39b shows the curve calculated from equation [5.22] for