Composite (metal deck with concrete topping) floor slabs in the modules are canti-
levered up to 11.3 m from the core and supported by discontinuous steel perimeter
columns down through the height of the modules. The bottom slab of each module
is a strengthened cantilever floor slab which supports the perimeter columns of the
upper storeys in the module. Strengthened cantilever slabs of modules protrude from
Reinforced concrete mega core
(circular cross-section with
varying external dimater and
wall thickness of 18 to 13m and 2 to lm
respectively from bottom to top)
Reinforced concrete
mega core
Discontinuous
perimeter column
Strengthened
cantilever
slab
,11.3mp
13-18m
i,11.3m ■
(UP10)
35.6-40.6m (UP ^
Health club & presidential suite floor
Hotel floor
Figure 4.10 Aspire Tower plan, section and structural axonometric
 