Environmental Engineering Reference
In-Depth Information
Ta b l e 5 . 5 Results obtained for measurements on sand samples mixed with deionized water,
at ten different moisture levels. The estimated values for σ 0 , C S ; σ 0 , TLM ;andσ 0 , ICM and for
the corresponding standard uncertainties are compared
θ
σ 0 , C S
σ 0 , TLM
σ 0 , ICM
(mS m 1 )
1 )
1 )
(%)
(
S
(
S
0.0
-
0.0
-
.
±
.
.
±
.
2.0
0
6
0
1
0.8
0
7
0
1
4.0
1 . 4 ± 0 . 1
1.6
1 . 6 ± 0 . 1
6.0
2
.
6
±
0
.
2
2.9
2
.
9
±
0
.
1
9.1
3 . 6 ± 0 . 3
4.1
4 . 0 ± 0 . 1
12.1
4
.
2
±
0
.
3
4.7
4
.
6
±
0
.
1
15.1
5 . 7 ± 0 . 4
6.4
6 . 3 ± 0 . 1
18.1
7
.
3
±
0
.
6
8.1
8
.
0
±
0
.
2
21.1
11 . 5 ± 0 . 9
12.7
12 . 4 ± 0 . 3
24.4
15 . 7 ± 1 . 2
17.3
16 . 9 ± 0 . 4
Ta b l e 5 . 6 Results obtained for measurements on sand samples mixed with salted water, at
ten different moisture levels. The estimated values for σ 0 , C S , σ 0 , TLM and σ 0 , ICM and for the
corresponding standard uncertainties are compared
θ
σ 0 , C S
σ 0 , TLM
σ 0 , ICM
(mS m 1 )
1 )
1 )
(%)
(
S
(
S
0.0
-
0.0
-
2.0
0 . 8 ± 0 . 1
1.0
1 . 0 ± 0 . 1
4.0
2 . 5 ± 0 . 2
2.8
2 . 7 ± 0 . 1
6.0
4 . 1 ± 0 . 3
4.6
4 . 5 ± 0 . 1
9.1
6 . 3 ± 0 . 5
7.0
6 . 9 ± 0 . 2
12.1
9 . 9 ± 0 . 8
11.0
10 . 8 ± 0 . 3
15.1
14 . 3 ± 1 . 1
15.8
15 . 6 ± 0 . 4
18.1
20 . 2 ± 1 . 5
22.3
21 . 8 ± 0 . 5
.
±
.
.
±
.
21.1
30
7
2
3
33.8
33
0
0
8
24.5
41 . 5 ± 3 . 1
45.6
44 . 6 ± 1 . 1
Finally, it must be pointed out that the K p , C S was evaluated through nine pre-
liminary measurements on the electrolyte solutions, and it was found that u Kp , C S
increases dramatically when less than nine points were considered for the linear re-
gression. Conversely, only two preliminary measurements were enough to obtain an
accurate estimation of the probe constant through the ICM method. This is one of
the major advantages of the described methods.
Search WWH ::