The screen shown in Figure 2-10 is the ILOM console; seeing it confirms the successful configuration of the
ILOM. Now that the ILOM is successfully configured, you can move on to configure the ODA database nodes.
The ILOM is always turned on as soon as the Database Appliance is cabled and powered on, but the server nodes
need to be manually powered on. Execute the following command from an ILOM-integrated shell session to power on
a server node. Be sure to execute the command for both nodes.
# start /SYS
The server node can also be powered on via the ILOM GUI accessible through a browser. ODA V1 and ODA
X3-2 have slightly different screens from which to perform various server power-related activities. Figure 2-11 and
Figure 2-12 show the screens for V1 and X3-2, respectively.