Listing 7-3 displays the output that is expected from running a system components check on the ODA V1. This
output will differ depending on the version of OAK software that is running. This means the output in Listing 7-3 is
provided as an example.
Listing 7-3. Validating ODA V1 System Components (ODA 2.6)
root@oda1 bin]# ./oakcli validate -c SystemComponents
INFO: oak system information and Validations
RESULT: System Software inventory details
Reading the metadata. It takes a while...
System Version Component Name Installed Version Supported Version
-------------- --------------- ------------------ -----------------
2.6.0.0.0
Controller 11.05.02.00 Up-to-date
Expander 0342 Up-to-date
SSD_SHARED E12B Up-to-date
HDD_LOCAL SA03 Up-to-date
HDD_SHARED 0B25 Up-to-date
ILOM 3.0.16.22.b r78329 Up-to-date
BIOS 12010310 Up-to-date
IPMI 1.8.10.5 Up-to-date
HMP 2.2.6.1 Up-to-date
OAK 2.6.0.0.0 Up-to-date
OEL 5.8 Up-to-date
TFA 2.5.1.4 Up-to-date
GI_HOME 11.2.0.3.6(16056266, Up-to-date
16083653)
DB_HOME 11.2.0.3.6(16056266, Up-to-date
16083653)
ASR 4.4 Up-to-date
RESULT: System Information:-
Manufacturer:ORACLE CORPORATION
Product Name:SUN FIRE X4370 M2 SERVER
Serial Number:XXXXXXXXXXXX
RESULT: BIOS Information:-
Vendor:American Megatrends Inc.
Version:12010310
Release Date:08/14/2012
BIOS Revision:1.3
Firmware Revision:1.3
SUCCESS: Controller p1 has the IR Bypass mode set correctly
SUCCESS: Controller p2 has the IR Bypass mode set correctly
INFO: Reading ilom data, may take short while..
INFO: Read the ilom data. Doing Validations
RESULT: System ILOM Version: 3.0.16.22.b r78329
RESULT: System BMC firmware version 3.0
RESULT: Powersupply PS0 V_IN=206 Volts I_IN=2 Amps V_OUT=12.16 Volts I_OUT=30.80
Amps IN_POWER=420 Watts OUT_POWER=390 Watts
RESULT: Powersupply PS1 V_IN=208 Volts I_IN=2 Amps V_OUT=12.16 Volts I_OUT=30.20
Amps IN_POWER=420 Watts OUT_POWER=370 Watts