Fig. 13
Simulation A.1 illustrating an energy efficient behavioural scenario
Fig. 14
Simulation A.2 illustrating an energy inefficient behavioural scenario
and 19 are performed when applying the static and dynamic algorithm, respec-
tively. It is possible to verify that the dynamic algorithm does not guarantee the
best residual; however, it is always better than the static algorithm. Moreover, it
provides a predication error of less than 2 % for these simulations. These residuals
are the absolute value of the difference between the building energy consumption
and the ECM prediction in percentage relatively to the building.