inline drippers were fi xed at spacing of 50 cm. The number of laterals installed was
based on the number of rows of crops grown. The discharge rate of single dripper is
4 L per hour.
Sub main and laterals were closed at the end with the end cap. Laterals were placed
for each row per plot and in between two rows per plot, with 11 emitters in each lateral
at a discharge rate of 4 L per hour. Irrigation scheduling at 65, 75, and 85% of irriga-
tion requirement for each day was commenced after the transplanting.
12.2.2 EXPERIMENTAL DESIGN
The experiment was laid out with seven treatments, combination consisting of three
irrigation levels and two drip system layouts. The experiment was laid out in random-
ized block design having seven treatment combinations and was replicated thrice. The
treatment details are shown in Table 1.
Main plots
Irrigation levels
I1
65% of the daily irrigation requirement
I2
75% of the daily irrigation requirement
I3
85% of the daily irrigation requirement
Sub plots
Drip system layout
D1
One lateral in between two rows of crop in a bed
D2
One lateral for each row of crop in a bed.
TABLE 1
Treatment details.
Treatment
Description
T1
65% of the daily irrigation requirement, with one lateral for each row
of crops in a bed.
T2
65% of the daily irrigation requirement, with one lateral in between
two rows of crop in a bed.
T3
75% of the daily irrigation requirement, with one lateral for each row
of crops in a bed.
T4
75% of the daily irrigation requirement, with one lateral in between
two rows of crop in a bed.
T5
85% of the daily irrigation requirement, with one lateral for each row
of crops in a bed.
T6
85% of the daily irrigation requirement, with one lateral in between
two rows of crop in a bed.
T7
Control
 