42.
Click on the upper bend face, and click OK.
43.
Activate the Closed Corner command (click Home > Corner > Closed
Corner on the ribbon) and click on the bends of the flange features.
44.
On the Closed Corner dialog, select Type > Close and Relief . Under Corner
Properties section, select Treatment > Circular Cutout .
45.
Under the Relief Properties section, set the (D) Diameter value to 8 mm. Click
OK to close the bends.