Meter
Feet
1000
3000
900
800
700
600
500
400
300
250
200
180
160
140
120
10 9 80
70
60
50
40
35
30
25
20
15
Region of impulse turbines
2000
1000
800
600
500
400
300
Region of Francis turbines
200
100
80
60
50
40
30
Region of propeller turbines
10
20
20000 30000 40000 60000 ft 3 /s
40
50 60
80 100
200
300 400 500 600 800 1000
2000
3000 4000 6000 8000 10000
10
1.5
2 2.3 3
4
5 6 7 8 9 10
15
20 25 30
40 50 60 70 80 100
150 200 250 300 400 500 600 800 1000 1500
106-D-348
m 3 /s
Turbine Discharge
FIGURE 3.10
Reaction turbine sizing relative to head and low. (From Iwabuchi, K. et al. 2006. Advanced Governor Controller for Pumped-Storage Power Plant and
Its Simulation Tool. SICE-ICASE International Joint Conference. Korea. IEEE Explore , pp. 6064-6068. With permission.)
 