Environmental Engineering Reference
In-Depth Information
River
Former
foundry
Trucking
firm
Closed
landfill
Former
landfill
Farmland and
former shooting
range
FIGURE 14.22
Urban setting of New Jersey site.
Each of the over
100 dots represent
an area of concern
River flow
direction
N
Lift station
7
50 m
0
50 m
0
8
15
16
4
23
14
17
22
12
11
3
21
10
9
18
24
19
20
13
2
FIGURE 14.23
Location of RECs for the foundry portion of the site.
detected in groundwater included low levels of LNAPL VOCs, PAHs, and SVOCs, with
none requiring remediation except for several areas with PAH-free product. Contaminants
requiring remediation in soil included PAHs, PCBs, lead, and mercury.
Figure 14.23 shows most of the RECs are associated with the foundry located along the
river on the west-northwest portion of the site. Within and near the foundry, the sources of
contamination included sumps, pits, trenches, floor drains, and outdoor storage of waste
materials where accidental spills had occurred.
Search WWH ::