Fig. 4.28 SS304 CCD empirical modeling
Fig. 4.29 G5 titanium CCD empirical modeling
Overall, when comparing the experimental data to the modeled data, the newly
introduced flow stress predictor does an accurate job at estimating the flow stress
for a CCD. It should be noted that for the NCCD and CCD flow stress predictors,
the variables K ′, n , and m are temperature sensitive values; however, the room tem-
perature values were used as the modifying terms introduced in the model account
for the temperature sensitivity of these values.