Civil Engineering Reference
In-Depth Information
Table 1.8
Ratio of wire diameter d to nominal rope diameter d for ropes with measured diameter d m = 1.025 d, and fill factor f, Jenner ( 1992 )
6-strand ropes
8-strand ropes
Filler
Seale
Warrington
Warr.-
Seale
Filler
Seale
Warrington
Warr.-
Seale
Wire ropes with fibre core
Fill factor
f
0.506
0.492
0.502
0.508
0.456
0.443
0.452
0.458
Strand
d 0 /d
0.06839
0.08851
0.07100
0.06103
0.05626
0.07280
0.05842
0.05021
di/d
0.06732
0.04540
0.06986
0.04663
0.05539
0.03735
0.05748
0.03836
d 2 /d
0.06324
0.07862
0.07223
0.04458
0.05202
0.06468
0.05943
0.03668
0.02765
-
0.05473
0.03444
0.02275
-
0.04503
0.02833
d 3 /d
-
-
-
0.05579
-
-
-
0.04590
Wire rope with steel core
Fill factor f 0.627 0.616 0.623 0.628 0.631 0.620 0.625 0.630
Centre strand do/d 0.05403 0.05555 0.05403 0.05337 0.06627 0.06682 0.06627 0.06559
di/d 0.05134 0.05277 0.05134 0.0507 0.06291 0.06342 0.06291 0.06234
1. Strand layer d 0 /d 0.04311 0.04344 0.04311 0.04301 0.05551 0.05585 0.05551 0.05563
di/d 0.04092 0.04126 0.04092 0.0408 0.0527 0.05302 0.05270 0.05283
2. Strand layer do/d 0.07025 0.09092 0.07294 0.06263 0.05786 0.07496 0.06010 0.05160
di/d 0.06916 0.04664 0.07176 0.04789 0.05696 0.03833 0.05909 0.03940
d 2 /d 0.06496 0.08076 0.07420 0.04579 0.05349 0.06670 0.06111 0.03772
0.02840 - 0.05622 0.03535 0.02344 - 0.04631 0.02910
d 3 /d - - - 0.05724 - - - 0.04712
Strand lay angle b = 20, outer wire lay angle a = 15, strand clearance (s S /d S ) FC = 0.05, (s S /d S ) WRC = 0.01, clearance outer wire layer s w /d 1 = 0.02,
clearance first wire layer S W = 0
Search WWH ::




Custom Search