Civil Engineering Reference
In-Depth Information
Table 2.10
Constants a
i
for the number of load cycles of stranded wire ropes for (
2.102
), metal sockets
Reference
Wire ropes
Nominal
diameter
d
Nominal
strength
R
o
Test
frequenzy
Free
rope
length
Number
of tests
Constants
Standard
deviation
N for d = 16
mm, S
u
/
d
2
= 20, 2S
a
/
d
2
= 200 N/
mm
2
N/mm
2
mm
Hz
L/d
n
a
0
a
1
a
2
a
3
a
4
lg s
Müller
(
1962
,
1963
,
1966
)
Cross lay ropes
6 9 19—
NSC—sZ
2.5
2,160
4.7
320
1/1
Lubricated
3.2
1,570
4.7
280
5/3
5.0
1,770
4.2
190
4/5
14.03
-3.461
-
-
-1.021
0.393
68,200
8.5
1,570
4.2
110
6/7
Unlubricated
16
1,570
3.0
65
7/6
12.82
-3.215
-
-
-0.718
0.385
35,800
3.0
b
6/6
c
28
1,570
27
Müller
(
1962
,
1963
,
1966
)
Cross lay ropes
6 9 19—
NFC—zZ
2.5
2,160
4.7
320
1/1
Unlubricated
3.2
1,570
4.7
280
3/3
5.0
1,770
4.2
190
5/5
12.74
-3.205
-
-
-0.535
0.178
52,700
8.5
1,570
4.2
110
5/6
Unlubricated
16
1,570
3.0
40
4/6
13.08
-3.245
-
-
-0.821
0.341
42,200
3.0
b
7/6
c
28
1,570
27
Filler
a
6 9 19—
NSC—zZ
Müller
(
1962
,
1963
,
1966
)
Lubricated
16
1,570
3.0
50
2/2
18.740
-5.729
-
-
-
-
381,000
2/2
c
Unlubricated
15.324
-4.470
-
-
-
-
109,000
Seale
a
6 9 19—
NSC—sZ
lubricated
Müller
(
1962
,
1963
,
1966
)
16
1,570
3.0
50
5
16.055
-4.680
-
-
-
0.021
193,000
Filler
a
8 9 19—
NSC—sZ
lubricated
Müller
(
1962
,
1963
,
1966
)
16
1,570
3.0
50
5
16.891
-5.476
-
-
-
0.055
136,000
Search WWH ::