Civil Engineering Reference
In-Depth Information
Table 9.1 Technical parameters of generation power plants fed by natural gas, solid biomass,
liquid biomass, and standard coal
DG¼distributed
generation;
UP¼utility plant
Electrical
efficiency (%)
Heat recovery
efficiency (%)
Technology
Fuel
Reciprocating
engine
35-45 %
45-35 %
Natural gas
DG
Gas turbine
25-35 %
55-45 %
Natural gas
DG
Micro gas
turbine
18-20 %
62-60 %
Natural gas
DG
Boiler and
backpressure
steam turbine
12-20 %
68-60 %
Natural gas
DG
Boiler and
backpressure
steam turbine
15 %
65 %
Solid Biomass
DG
Reciprocating
engine
35-40 %
45-40 %
Liquid Biomass
DG
Utility plant
combined cycle
800-1,000 MW
60 %
0
Natural gas
UP
Utility plant,
steam condensing
turbine
26 %
0
Coal
UP
NOT RECOVERABLE HEAT
COMBUSTION AIR
LOSSES
COGENERATION PLANT
ELECTRIC GENERATOR
NATURAL GAS
ELECTRICAL ENERGY
LOSSES
HEAT RECOVERY
100%
F
40%
H
40%
E
20%
L
50% Net heat recovery index (1)
30.8% Primary Energy Saving index(2)
2,500 kW
1,000
kW
1,000 kW
500
kW
104.9 Sm 3 /h
(3)
3
3
3
262.2 Sm
/h
116.5 Sm
/h
(
=
145.7
Sm
/h
3
Sm
/kWh
0.146
input data
(1) H/(H+E)
(2) (1-F/(E/ p +H/ b ))*100
(4)= (3)/ b
where h p =electrical production and transmission efficiency=40% and h b =efficiency of the boiler to replace=90%
natural gas LHV=34,325 kJ/Sm 3
Fig. 9.1 Basic scheme of a cogeneration plant