(c) Experimental section which employed admixture.
The
first slab: 3 cracks; the overall length was 12 cm.
The second slab: 7 cracks; the overall length was 57 cm.
The third slab: No crack.
The fourth slab: 2 cracks; the overall length was 5 cm.
The
fifth slab: No cracks.
The sixth slab: No cracks.
Figure 16.17 shows photographs of the
first slab (three clear cracks) and the
second slab (
ne and short crack).
Twelve cracks were found in experimental section which employed admixture,
and their total length was 74 cm.
16.3.5 Experiment on Penetration Speed
During the curing process, crews that were responsible for curing found that pen-
etration speed of concrete which was treated by troweling machine was much
Fig. 16.17 Cracks on slab