Table 26.2 Geometrical and mechanical properties used in experimental design
Property
Range
Property
Range
Rotor diameter,
RD (m)
40-126
Soil elasticity
modulus, E soil (MPa)
13-200
Tower height,
H 1 (m)
40-80
Friction between pile
and soil,
0.2-0.3
μ
Tower top
diameter, D 1 (m)
1.9-4.0
Soil type
Clay
Sand
Tower base
diameter, D 2 (m)
3.0-6.0
Soil cohesion, C soil
(kPa)
10-200
0-80
Tower diameter to
thickness ratio
100-200
Soil friction angle,
ϕ
10-25
35-45
soil (°)
Water depth,
WD (m)
20-30
Mean wind speed, W s
(m/s)
3.0-30
Marin segment
height, H 2 (m)
WD
+
(2.5-10)
Turbulence intensity,
IT w
0-0.16
Steel type
S235, S275,
S355
Signifi cant wave
height, H s (m)
1.0-10
Tower vibration
period, T n (s)
0.9-11.9
Signifi cant wave
period, T p (s)
36
.
H
50
.
H
s
s
Pile penetration, H 3
10-50
Pile diameter to
thickness ratio
50-100
Rated wind speed,
W s_ rated (m/s)
10.3-11.7
Table 26.3 Bins from which ground motions are selected
Distance
(km)
No. of
records
Bin no.
Bin characteristics
Magnitude
1
Large magnitude, small distance
M > 6.5
13 < R < 30
20
2
Large magnitude, large distance
M > 6.5
R > 30
20
3
Small magnitude, small distance
M < 6.5
13 < R < 30
20
4
Small magnitude, large distance
M < 6.5
R > 30
20
5
Near fault
M > 6.5
R < 13
20
records should capture the characteristics of the possible seismic hazards,
including their return periods, intensities, frequency contents, and durations
(Krawinkler et al. , 2003). We select ground motion records from the PEER
(Pacifi c Earthquake Engineering Research Center) NGA database (1999).
Following Shome and Cornell (1999), the selected ground motions are
subdivided into fi ve bins based on moment magnitude ( M ) and the closest
distance between the record location and the rupture zone ( R ). Table 26.3
shows the bins from which the ground motions are selected. Each bin rep-
Search WWH ::