Digital Signal Processing Reference
In-Depth Information
Chap. 12 , where the ANN structures and other issues important for their appli-
cation purpose are described.
References
1. Bunyagul T, Crossley P, Galac P (2001) Overcurrent protection using signals derived from
saturated measurement CTs. In: Proceedings of PES summer meeting, Vancouver, vol 1,
pp 103-108
2. Chen KW, Glad ST (1991) Estimation of the primary current in a saturated transformer. In:
Proceedings of 30th conference on decision and control, Brighton, England, vol 3, pp 2363-
2365
3. Kang YC, Park JK, Kang SH, Johns AT, Aggarwal RK (1996) Development and hardware
implementation
of
a
compensating
algorithm
for
the
secondary
current
of
current
transformers. IEE Proc Electr Power Appl 243:41-49
4. Kang YC, Park JK, Kang SH, Johns AT, Aggarwal RK (1997) An algorithm for
compensating secondary current of current transformer. IEEE Trans Power Deliv 12:116-124
5. Kang YC, Lim UJ, Kang SH (2004) Compensating algorithm for the secondary current for
use with measuring type current transformers. In: Proceedings of the international conference
advanced power system automation and protection, Jeju, Korea, pp 3-8
6. Kasztenny B, Mazereeuw J, Jones K (2001) CT saturation in industrial applications—
analysis and application guidelines. Publ GET-8501 GE Multilin, Canada
7. Li F, Li Y, Aggarwal RK (2002) Combined wavelet transform and regression technique for
secondary current compensation of current transformer. IEE Proc Gener Transm Distrib
149:497-503
8. Rebizant W, Bejmert D (2007) Current-transformer saturation detection with genetically
optimized neural networks. IEEE Trans Power Deliv 22:820-827
9. Rebizant W, Hayder T, Schiel L (2004) Prediction of CT saturation period for differential
relay adaptation purposes. In: Proceedings of the international conference on advanced power
system automation and protection, Jeju, Korea, pp 17-22
10. Rebizant W, Bejmert D, Staszewski J, Schiel L (2007) CT saturation detection and correction
with artificial neural networks. In: Proceedings of the 2nd international conference on
advanced power system automation and protection, Jeju, Korea, paper 504
11. Rebizant W, Wiszniewski A, Schiel L (2008) CT saturation correction based on the estimated
CT saturation time constant. In: Proceedings of the 8th international IET conference
developments in power system protection, Glasgow, UK, pp 174-179
12. Saha MM, I zykowski J, Łukowicz M, Rosołowski E (2001) Application of ANN method for
instrument transformer correction in transmission line protection. In: Proceedings of the IEE
development in power system protection, Conf Publ No 479, pp 303-306
13. Wiszniewski A, Rebizant W, Schiel L (2008) Correction of current transformers transient
performance. IEEE Trans Power Deliv 23:624-632
14. Yu DC, Cummins JC, Wang Z, Yoon HJ, Kojovic LA (2001) Correction of current
transformer distorted secondary current due to saturation using artificial neural networks.
IEEE Trans Power Deliv 16:189-194