Chemistry Reference
In-Depth Information
Table 8.2 Analysis of samples used for spiking recovery tests
Sample
BOD/
mg
L −1
Suspended
solids at
105°Cl mg
L −1
Ammonia
(as N)/
mg L −1
Total
oxidised
nitrogen
(as N)/
mg L −1
pH
Electrical
conductively/
µS cm −1
Anionic
detergent
(Manoxol
OT) mg
L −1
Clean river
water 1
1.5
5
0.14
0.35 6.6
90
-
Clean river
water 2
0.3
1
0.41
1.8 7.2
475
-
Peaty stream
water
2.1
7
0.29
0.8 6.6
100
-
Good sewage
effluent
9.6
17
2.6
28.0 6.8
580
-
Poor sewage
effluent
30.0
31
14.8
17.1 7.0
560
-
Septic tank
effluent
-
56
17.2
0.2 7.4
800
-
Maltings
effluent
234
80
1.8
0.1 7.2
1200
-
Detergent
manufacture
effluent
8.0
13
0.2
0.6 7.5
720
0.16
Surface water
from detergent
manufacture
1.2
2
0.8
17.0 7.5
3000
0.37
Petrochemical
treatment plant
effluent
270
84
28.8
0.1 6.5
760
-
Source: Reproduced with permission from the Royal Society of Chemistry [7]
Table 8.3 Species producing interference
Interfering
species
Level producing
interference/ mg L −1
Interfering
species
Level producing
interference/ mg L −1
Chromium(VI)
10 Hydrogen
carbonate
1000