Civil Engineering Reference
In-Depth Information
(
)
(
)
φ
V n
V c
V s
10
f c h 0.8
ʹ
w
Table 6-5 gives values of
φ
V c
2
f c h0.8
ʹ
w
and limiting values of
,
both expressed in kips per foot length of wall.
Table 6-5 Design Values of
φ
V c and Maximum Allowable
φ
V n
Wall
Thickness
h (in.)
I V c
(kips/ft length of wall)
Max. I V n
(kips/ft length of wall)
6
5.5
27.3
8
7.3
36.4
10
9.1
45.5
12
10.9
54.6
The required amount of vertical shear reinforcement is given by ACI Eq. (11-30):
ρ ˜ = 0.0025 + 0.5(2.5 - h w w )(
ρ t - 0.0025)
where h w = total height of wall
ρ ˜ = A vn /s 1 h
ρ t = A vh /s 2 h
When the wall height-to-length ratio h w w is less than 0.5, the amount of vertical reinforcement is equal to the
amount of horizontal reinforcement (ACI 11.9.9.4).
6.4.1
Example 1: Design for Shear
To illustrate the simplified methods described above, determine the required shear reinforcement for the wall
shown in Fig. 6-3. The service shear force from the wind loading is 160 kips. Assume total height of wall from
base to top is 20 ft.
Figure 6-3 Plan View of Shearwall
Search WWH ::