Environmental Engineering Reference
In-Depth Information
TABLE 2.1
Specifications of the Test Furnace
Furnace size
1000 mm in length,1000 mm in width, 1000 mm in height
In-furnace temperature
Maximum, 1300˚C
Combusting apparaus
Combusting volume: maximum
58 kW (50,000 kcal/h) pair
Fuel:
13A, LPG
Pressue:
fuel
2000 mmAq
air 800 mm Aq
Incidental facilities
Combusting air feeding fan
Exhausting facility (IDF)
Compressor
Fuel nozzles
to be measured
Hole for preheated air
FIGURE 2.13 Burner nozzles.
Test
furnace
CCD
Cameras
Burners
SHG unit
SHG unit
Dye
Laser
Nd:YAG
Laser
Excimer
Laser
Optical system
Pulse
generator
Controller
FIGURE 2.14 Laser induced fluorescence (LIF) measurement system.
 
 