TABLE 4.5
Examples of NO x in Continuous Reheating Furnace
Operating
Temperature,
K(˚C)
NO x Generation
(Equivalent to 11%
O 2 ), ppm
No.
Furnace Type
Fuel
Remarks
1.
Continuous WBF
LNG
1373 (1100)
89
Regeneration in all
zones
2.
Continuous WBF
Mix Gas
1423 (1150)
77
Regeneration in
preheating zone
3.
Continuous WBF
LNG
1323 (1050)
82
Regeneration in all
zones
4.
Continuous WBF
C-Heavy Oil
1323 (1050)
36
Regeneration in all
zones
5.
Continuous WBF
LNG
1483 (1210)
72
Regeneration in
preheating zone
6.
Continuous WBF
Mix Gas
1423 (1150)
30
Regeneration in
preheating zone
7.
Continuous PF
LNG
1623 (1350)
40
Regeneration in all
lower zones
8.
Continuous WBF
COG
1453 (1180)
34
Regeneration in
preheating zone
Note :
WBF: Walking beam furnace, PF: Pusher furnace.