Environmental Engineering Reference
In-Depth Information
pressure regulator
pressure
gauge
pressure
gauge
nozzle
H.P. hose
Oval flow
meter
liquid fuel
gas strainer
FIGURE 2.75 Schematic diagram of the whole installation for liquid fuel injection.
100
100
FIGURE 2.76 Configuration of heat reservoir.
by the two factors of the liquid axis direction at the outlet of nozzle and the velocity
component in the rotating direction. The divergent spray cone angle of 60˚ was
adopted in the present experiment.
In the figure, a hole for inserting the spray nozzle is arranged at the side of the
furnace. The reason for arranging this hole in such a way is to compare the flame
of liquid fuel in a cross-flowing state with results previously obtained for gaseous
fuel. The fuel spray flow is injected through this hole at a right angle to the diluted
airflow already preheated at a high temperature. However, in the case of the exper-
imental furnace, because the respective blower outputs of absorption and exhaust
are sometimes out of balance to produce a possible negative pressure, a great quantity
of air outside of the furnace might be sucked in through the hole during measurement.
 
Search WWH ::