TABLE 11.3 (continued)
Freundlich Parameters (log (
q
) = log (
K
) +
n
log (
c
)) Obtained for the Activated Carbon Epibon Y12×40 (Sieved 63-125 μm)
Compound
AC Lot
Analytics
K
±σ
N
±σ
r
2
N
c
0
/mg L
−1
2-Methylquinoline (buffer pH = 2.9) New HPLC 48 2 0.20 0.02 0.9333 13 16.35
2-Methylquinoline (buffer pH = 7) New HPLC 145 6 0.23 0.02 0.9146 11 24.22
2-Methylquinoline (in water) New HPLC 167 8 0.19 0.01 0.9562 11 13.02
Phenanthridine (buffer pH = 7.0) New HPLC 171 15 0.29 0.03 0.9145 11 2.00
Phenanthridine (buffer pH = 2.5) New HPLC 144 3 0.11 0.01 0.8829 10 9.37
Acridine New HPLC 298 42 0.26 0.04 0.8615 8 13.29
9-Methylacridine New HPLC 427 20 0.12 0.01 0.9497 13 2.49
Carbazole New HPLC 319 19 0.22 0.01 0.9473 16 0.58/0.66
Note:
Measurements were performed in deionized water and in buffer mixtures; temperature for all measurements
T
± σ = 20 ± 3°C.
Standard deviations are errors from linear regressions performed. AC lot = two lots obtained from the supplier Donau Carbon were
used (old lot 1 kg; (April 2006), new lot 20 kg (July 2008); Analytics = analytical method used;
K
(unit mg
1−
n
g
−1
L
n
) and
n
(without a unit)
are the Freundlich parameters with standard deviations;
r
2
= goodness of it of the linear regression from log (
q
) versus log (
c
);
N
= number of data points; and
c
0
= start concentration in mg/L.