growth yield under uncoupler addition conditions; K
s/x
is saturation constant related to S
0
/X
0
;
K
u/x
is saturation constant related to C
u
/X; X is biomass concentration at the instant of
uncoupler addition; S
0
is initial substrate concentration.
3.5. Molecular Analyses
Microbial populations at the presence of uncouplers can be monitored by several
molecular analyses, such as PCR amplification of 16S rRNA genes followed by denaturing
gradient gel electrophoresis (DGGE). These two microbiological techniques are always
combined together to determine the molecular composition of the microbial community.
Besides, Polyacrylamide Gel Electrphoresis (PAGE) is also frequently used to analyze the
active biomass with small molecular weight RNA [87].
References
[1]
Liu, Y. (2003) Chemically reduced excess sludge production in the activated sludge
process.
Chemosphere
50
(1), 1-7.
Metcalf and Eddy. (1991)
Wastewater engineering, treatment disposal and reuse
. 3
rd
ed, Mcgraw-Hill, Inc USA.
[2]
[3]
Andreottola, G. and Foladori, P. (2005) A review and assessment of emerging
technologies for the minimization of excess sludge production in wastewater treatment
plants.
J Environ Sci Health A Tox Hazard Subst Environ Eng
41
(9), 1853-1872.
[4]
Zheng, G.H., Li, M.N., Wang, L., Chen, Z.Y., Qian, Y.F. and Zhou, Q. (2008)
Feasibility of 2,4,6-trichlorophenol and malonic acid as metabolic uncoupler for sludge
reduction in the sequence batch reactor for treating organic wastewater.
Appl Biochem
Biotechnol
144
(2), 101-109.
[5]
Wei, Y.S., Van Houten, R.T., Borger, A.R., Eikelboom, D.H. and Fan, Y.B. (2003)
Minimization of excess sludge production for biological wastewater treatment.
Water
Res
37
(18), 4453-4467.
[6]
Liu, Y. and Tay, J.H. (2001) Strategy for minimization of excess sludge production
from the activated sludge process.
Biotechnol Adv
19
(2), 97-107.
[7]
Mayhew, M. and Stephenson, T. (1998) Biomass yield reduction: Is biochemical
manipulation possible without affecting activated sludge process efficiency?.
Water Sci
Technol
38
(8-9), 137-144.
[8]
Saiki, Y., Imabayashi, S., Iwabuchi, C., Kitagawa, Y., Okumura, Y. and Kawamura, H.
(1999) Solubilization of excess activated sludge by self-digestion.
Water Res
33
(8),
1864-1870.
[9]
Yasui, H. and Shibata, M. (1994) An innovative approach to reduce excess sludge
production in the activated sludge process.
Water Sci Technol
30
(9), 11-20.
[10]
Tsuno, H., Arakawa, K., Kato, Y. and Nagare, H. (2008) Advanced sewage treatment
with ozone under excess sludge reduction, disinfection and removal of EDCs.
Ozone-
Sci Eng
30
(3), 238-245.
[11]
Saby, S., Djafer, M. and Chen, G.H. (2002) Feasibility of using a chlorination step to
reduce excess sludge in activated sludge process.
Water Res
36
(3), 656-666.