Hardware Reference
In-Depth Information
Commercial diagnostics software —A number of manufacturers make general-purpose
diagnostics software for PCs. This type of software is often bundled with other system
maintenance and repair tools to form a general PC software toolkit.
Free/open-source diagnostics software —A large number of free or open-source diagnostic
programs are available for PCs, including small task-specific programs as well as complete
collections of diagnostics in bootable form.
The POST
When IBM began shipping the original PC in 1981, it included safety features that had never been
seen in a personal computer. These features were the POST and parity-checked memory. Although
parity-checked or even error-correcting code (ECC) memory is no longer available in most non-
server chipsets, every PC still executes a POST when you turn it on. The following sections provide
more detail on the POST, a series of program routines buried in the motherboard ROM-BIOS chip
that tests all the main system components at power-on time. This series of routines is partially
responsible for the delay when you turn on your PC; the computer executes the POST before loading
the operating system.
These tests check the primary components in your system, such as the CPU, ROM, motherboard
support circuitry, memory, and major peripherals such as the expansion chassis. These tests are brief
and are designed to catch hard (not intermittent) errors. The POST procedures are not very thorough
compared to available disk-based diagnostics. The POST process provides error or warning
messages whenever it encounters a faulty component.
Although the diagnostics performed by the system POST are not thorough, they are the first line of
defense, especially when it comes to detecting severe motherboard problems. If the POST encounters
a problem severe enough to keep the system from operating properly, it halts the system boot process
and generates an error message that often identifies the cause of the problem. These POST-detected
problems are sometimes called fatal errors because they prevent the system from booting.
Systems that use UEFI firmware also perform diagnostics tests, but depending upon the specific
firmware in use, error messages may be stored in event logs, and beep codes may be used for some
errors.
How Errors Are Displayed
The POST tests normally provide three types of output messages: audio codes, onscreen text
messages, and hexadecimal numeric codes that are sent to an I/O port address.
POST errors can be displayed in the following three ways:
Beep codes —Heard through the speaker or beeper attached to the motherboard. Note that some
systems do not include a speaker.
POST checkpoint codes —Hexadecimal checkpoint codes sent to an I/O port address. A
special card plugged into an available expansion slot is required to view these codes.
Onscreen messages —Error messages displayed onscreen after the video adapter is
initialized.
Systems that use UEFI firmware might use beep and checkpoint codes but also store error messages
in event logs.
BIOS POST Beep Codes
 
 