Civil Engineering Reference
In-Depth Information
iel element counter
iflag failure flag
incs number of load increments
is location of desired output freedom
it processor on which desired output resides
iters iteration counter
iy simple counter
j simple counter
jflag failure flag
jj simple counter
k simple counter
l simple counter
lalfa length of alfa array
leig length of eig array
limit iteration ceiling
loaded_freedoms number of loaded freedoms
loaded_nodes
number of loaded nodes
output channel number
lp
problem dependent array size
lx
problem dependent array size
lz
ndim
number of dimensions
problem dependent array size
neig
temporary equation sum
neq_temp
nip
number of integrating points
nle
number of loaded elements (side of square)
number of eigenmodes computed
nmodes
number of nodes in the mesh
nn
temporary node sum
nn_temp
number of nodes per element
nod
number of pressure degrees of freedom per element
nodf
number of degrees of freedom per node
nodof
start address of loaded/fixed freedoms
no_index_start
print interval
npri
number of restrained nodes
nr
number of output freedom
nres
timestep counter
ns
number of stress-strain terms
nst
number of timesteps in analysis
nstep
number of processors holding load/displacement data
num_no
number of elements in
x
direction
nxe
number of elements in
y
direction
nye
number of elements in
z
direction
nze
total number of degrees of freedom per element
n_t
plastic iteration counter
plasiters
plastic iteration ceiling
plasits